Cable Jointing - PhotoBlog

By Chris Dodds on 18th February, 2016

Joint : 400kV Prysmian Extended Ferrule Straight Joint. Location : Regents Canal Shoreditch East London UK. Cable Jointer : Steve Fielder. The EHV cable jointers on this installation were Steve Fielder and Matt Taffs while the fluid fitters ... Read More - Masterclass - 400kV ...


By Chris Dodds on 12th February, 2016

Image: Johnny Chan - Marketing Executive at Yangzhou Power Electric Co.,Ltd Pictured: 800kV Water Termination System For 500kV XLPE Cable Testing   Further reading World First : EHV 1,100kV GIS Tested By Standard L... Read More - 800kV Water Terminat...


By Chris Dodds on 8th February, 2016

Image: Darren Street Cable Jointer at D+R Jointing Services Ltd Pictured: Pfisterer Connex Cable Plugs Terminating XLPE Cable Into 11kV/33kV Transformer - the Connex cable terminations are shown connecting 33kV single core 500sqmm cables into... Read More - Pfisterer Connex Cab...


By Chris Dodds on 5th February, 2016

By Chris Barker (EHV Jointer). ABB 132kV Cable Terminations. Before we start, let us establish Chris Barker is an international class EHV Jointer conversant with the skills and techniques required for the safe jointing and terminating of cables... Read More - Masterclass - 132kV ...


By Chris Dodds on 5th February, 2016

Image: Darren Street - Cable Jointer at D+R Jointing Services Ltd. Pictured: 4 Core Waveform LV Cable Terminations Into Schneider Feeder Pillar.   Further reading Jointing Masterclass - Waveform Mains & Hybrid S... Read More - 4 Core Waveform LV C...


By Chris Dodds on 5th February, 2016

Image: Darren Street Cable Jointer at D+R Jointing Services Ltd. Pictured: Nexans Euromold Cable Connectors Terminating 11kV Cables Into Siemens NXPLUS Gas Insulated Switchgear (GIS).   Further reading 4 Core Waveform L... Read More - Nexans Euromold Cabl...


By Chris Dodds on 5th February, 2016

Image: Stephen Savage - EHV Cable Jointer at OCU Ltd. Pictured: 132kV Cross Bonded Sudkabel Cable Joints.   Further reading Sudkabel Cable Termination 115kV (GIS) With Oil Filled Terminations Installing 132kV Pry... Read More - 132kV Cross Bonded S...


By Chris Dodds on 5th February, 2016

Image: Stephen Savage - EHV Cable Jointer at OCU Ltd. Pictured: Nexans Euromold Connectors 440TB Interface C (11kV/33kV). T&D are Main Distributors for the complete range of Nexans Euromold Connectors, Joints and Terminations for mediu... Read More - Nexans Euromold Conn...


By Chris Dodds on 5th February, 2016

Image: Remus Bidireac - 11/33kV Cable Jointer at Schneider Electric. Pictured: Nexans Euromold T Bolt Cable Termination Connectors (11kV XLPE CTS AWA Cables) - cable terminations shown connected to Schneider Electric switchgear (SF6 Gas Insul... Read More - Nexans Euromold T Bo...


By Chris Dodds on 5th February, 2016

Image: Darren Street Cable Jointer at D+R Jointing Services Ltd. Pictured: 11kV Raychem Heat Shrink Cable Terminations Connecting Single Core XLPE AWA BS6622 Cables. Darren Street has worked for D + R Jointing for 14 years progressing from... Read More - 11kV Raychem Heat Sh...


By Chris Dodds on 5th February, 2016

Image: Scott Atkins - Sr. Cable Splicer at Georgia Power Company. Pictured: MV Transition Cable Splice In Manhole (300 MCM PILC To 350 MCM EPR). The stress relief mastic is used as an oil stop in this Raychem cable splice - it is... Read More - MV Raychem Transitio...


By Chris Dodds on 5th February, 2016

Image: Pete Thomasson - HV Cable Jointer / Linesman. Pictured: 3M QTIII Cold Shrink Cable Terminations (33kV/6.6kV Step-Down - XLPE Single). T&D stock an extensive range of 11kV-33kV 3M Cold Shrink Joints & Terminations for the joi... Read More - 3M QTIII Cold Shrink...


By Chris Dodds on 5th February, 2016

Image: Steve Amos HV/MV Jointer & Supervisor at RJ Power Ltd. Pictured: 11kV Tyco Coldshrink Triplex Cable Termination (WPD Specification) To G59 Bushings - the Tyco cable terminations are shown terminating the 11kV XLPE insulated ca... Read More - 11kV Tyco Coldshrink...


By Chris Dodds on 5th February, 2016

Image: Jeremy Hunt - HV & LV Engineering at Inter-Lect (UK) Ltd. Pictured: 33kV Euromold (Nexans) Connectors Terminating XLPE Cables Into Siemens Switchgear - the 33kV XLPE power cable was prepared using Boddingtons Cable J... Read More - 33kV Euromold (Nexan...


By Chris Dodds on 4th February, 2016

Image : John Penny Cable Jointer / Director at CableTec Services (SPEN & SSE Authorisations from LV up to 400kV). CableTec Services are experienced in all aspects of 11kV and 33kV cable jointing, terminating and medium voltage installatio... Read More - 11kV Trifurcating Tr...