Cable Jointing - PhotoBlog

By Chris Dodds on 6th January, 2016

Image: David Young - HV/EHV Cable Jointer at Balfour Beatty Utilities. Pictured: 275kV Fluid Filled Straight Cable Joints.   Further reading  275kV Fluid Filled Cable Cut And Capped After The Cable Pull  ... Read More - 275kV Fluid Filled S...


By Chris Dodds on 6th January, 2016

Image: Steve Fielder - HV/EHV Cable Jointer. Pictured: 110kV G&W Cable Termination - HPFF High Pressure Fluid Filled "It's a 110kV G&W cable termination, the system is high pressure fluid filled and the cables run ins... Read More - 110kV G&W Cable ...


By Chris Dodds on 6th January, 2016

Image: Fredrik Pedersen - HV Cable Jointer / Supervisor at OTERA RATEL. Pictured: 130kV Ericsson (NKT) Transition Cable Joint (EHV).    NKT Joints & Terminations Overview  Self-supporting outdoor c... Read More - 130kV Ericsson (NKT)...


By Chris Dodds on 6th January, 2016

Image: Barrie Gray (High Voltage Electrical Fitter). Pictured: 33kV 4000amp Fully Insulated Duresca Busbar System On Dudgion Offshore Platform. The cables that come from the turbine array strings are routed into the 33kV panelboard. The... Read More - 33kV 4000amp Fully I...


By Chris Dodds on 6th January, 2016

Image: Danny Williamson - LV/HV Cable Jointer. Pictured: 11kV Cooper Connectors Terminating MV Power Cables Onto GBE Transformer. Cooper Power Connectors - MV-HV Specifiers Guide 5kV-35kV     Further reading 3... Read More - 11kV Cooper Connecto...


By Chris Dodds on 6th January, 2016

Image: Richard Huston - High Voltage Cable Splicer at IBEW Local 17. Pictured: 345kV HPFF USI Full Stop Joint To Okonite 3500 KCM Cable. Richard Huston has 14 years experience of high voltage cable splicing/jointing up to 345kV. &nb... Read More - 345kV HPFF USI Full ...


By Chris Dodds on 6th January, 2016

Image: Andrew Brezovszky EHV Cable Jointer at Energex Australia. Pictured: Tyco Raychem Heat Shrink Pole Termination On 33kV LAT Cable With Pothead Earths. 33kV LAT cable 1000sqmm aluminium conductor terminated outdoor using Tyco/Raychem h... Read More - Tyco Raychem Heat Sh...


By Chris Dodds on 6th January, 2016

Image: Euan Palmer - EHV Cable Jointer (Grade 4) at Balfour Beatty Utility Solutions Ltd. Pictured: 11kV Heat Shrink Straight Transition Cable Joints (XLPE PILC Single Core 630sqmm). Tyco Raychem heat shrink cable joints used to achieve a ... Read More - 11kV Tyco Heat Shrin...


By Chris Dodds on 14th December, 2015

Images : Euan Palmer (EHV Cable Jointer (Grade 4) at Balfour Beatty Utility Solutions Ltd). Cable Jointers : Euan Palmer, Alex Hope, David Barnes. Founded in 1909, Balfour Beatty plc are a leading international infrastructure group with ov... Read More - Nexans Euromold 11kV...


By Chris Dodds on 10th December, 2015

Image: John Penny (Cable Jointer / Director at Cabletec Services) John Penny is an HV cable jointer and co-owner of Cabletec Services with over 21 years experience in the LV-HV power industry. Working primarily within SPEN networks bo... Read More - Pfisterer Connex Inn...


By Chris Dodds on 10th December, 2015

Image: Simon Chapman (Cable Jointer Balfour Beatty plc) Pictured: 132kV Oil Sealing End Repair Further reading 132kV Prysmian Oil Filled Stop Joint & 132kV Straight Joint 33kV Ericsson Medium Voltage Cable Joint - Oil Fi... Read More - 132kV Oil Sealing En...


By Chris Dodds on 3rd December, 2015

Image Courtesy : Dean Hughes (Cable Jointer - Freedom Group) Pictured : 3M Cold Shrink 11kV Terminations - the termination kits supplied under contract by Sicame UK to UK DNO, Scottish Power Energy Networks, are manufactured by 3M. The 11kV ter... Read More - Terminating 11kV Cab...


By Chris Dodds on 2nd December, 2015

Image: Andrew Brezovszky (EHV Cable Jointer at Energex Australia) Pictured: Temporary Caps Wiped On 110kV 1600sqmm Copper Corrugated XLPE Cable Further reading 33kV XLPE Lat Structure MV Cable Termination Using Raychem Hea... Read More - Temporary Caps Wiped...


By Chris Dodds on 2nd December, 2015

Image: David Young HV/EHV Cable Jointer at Balfour Beatty Utilities. Pictured: 275kV Fluid Filled Cable Cut & Capped After The Cable Pull More EHV Jointing by David Young :  275kV Fluid Filled Straight Cable Joint... Read More - 275kV Fluid Filled C...


By Chris Dodds on 2nd December, 2015

Image Courtesy : Jim Andrews (CCR Contracts Manager) Project : Airedale International Scope : CCR pulled, cleated and terminated several kilometres of LV 4 Core 300sqmm XLPE SWA cables. The 200 metre armoured cable runs located inside a... Read More - Perfecting Complex L...


Go back to blog index

< < Newest   |   < Newer   |   Page 10 of 16   |   Older >   |   Oldest > >