Pfisterer Connex Inner Cone Plug Cable Terminations - MV CONNEX & HV CONNEX

Pfisterer Plugs - Inner Cone Connex Plugs For HV Switchgear Pfisterer Inner Cone Plugs 

Pluggable Connection Systems

MV-CONNEX Separable Connectors, Size 0 - 3-S

HV-CONNEX Separable Connectors, Size 4 - 6-S

 

Pfisterer Connex meets all the requirements for a universal system of separable connectors. The Connex pluggable connection systems are fully insulated with metal housing, are easy to install and provide touch-proof properties. These separable connectors are also maintenance-free, suitable for outdoor use and waterproof - meaning they are suitable for the most extreme conditions.

Pfisterer Connex systems are available in a wide range of variants, ranging from conventional socket and plug combinations to many system extensions for testing purposes and special applications.

 

Pfisterer MV-CONNEX Separable Connectors, Size 0 to 3-S

- Medium Voltage Connex systems up to 52kV

Pfisterer HV-CONNEX Separable Connectors, Size 6 to 6-S

- High voltage Connex systems up to 245 kV

Pfisterer CONNEX Separable Connector System

11kV, 33kV, 52kV XLPE Cable Preparation For Terminating With Pfisterer Connex High Voltage Inner Cone Plugs 

"Fully-bonded" semi-conducting screen layers - use stop ring provided in Pfisterer Connex plugs against cable jacket cut. Using bonded screen removal/stripping tool peel the high voltage cable screen to the power cable jacket cut (dimension per Pfisterer Jointing Instruction). Ensure diameter of XLPE cable insulation lies within the diameter range of the Pfisterer Connex insulating part.

Easy-strip" semi-conducting screen layers - mark the extruded "easy-strip" removable semi-con layer (dimension per Pfisterer Connex Jointing Instruction). Roughen the high voltage (HV) cable screen with electrical-grade emery cloth with max. 120 grain (eg Al-Oxide 120 Grain). Use correct HV screen stripping pliers and set depth to level that ensures XLPE cable conductor is not damaged. Cut cable insulation and remove according to Pfisterer Connex instructions.

If in doubt, contact T&D or Pfisterer Connex for cable jointer advice.

Note : Pfisterer Connex Plugs should only be installed by Pfisterer Connex Trained Cable Jointers using correct approved Pfisterer Connex Tool Sets.

 

Adobe Enquiry Form - Pfisterer Connex Inner Cone Plugs

Adobe Pfisterer Connex Separable Connector Size 3S Plug - 33kV-42kV-52kV

Adobe Pfisterer Connex Inner Cone Plug Size 1 - 35-240sqmm, 11-33kV

Adobe Pfisterer Connex Inner Cone Plug Size 2 - 50-300sqmm, 11-42kV

Adobe Pfisterer Connex Inner Cone Plug, Size 3 - 95-630sqmm, 11-42kV

Adobe Pfisterer Connex Inner Cone Plug Size 3S - 95-630sqmm, 11-52kV

Adobe Pfisterer Connex Inner Cone Plug Size 4 - 95-1600sqmm 24-72.5kV

Adobe Pfisterer Connex Inner Cone Plug Size 5S - 95-1600sqmm, 145kV

Adobe Pfisterer Connex Inner Cone Plug Size 6 - 240-2000sqmm, 170kV

Adobe Pfisterer Connex Inner Cone Plug Size 6S - 240-2000sqmm, 245kV

Adobe Pfisterer Inner Cone Plug Terminations - Connex Size 0 Instruction

Adobe Pfisterer Inner Cone Plug Terminations - Connex Size 1 Instruction

Adobe Pfisterer Inner Cone Plug Terminations - Connex Size 2 Instruction

Adobe Pfisterer Inner Cone Plug Terminations - Connex Size 3 Instruction

Adobe 33kV Power Cable- Single Core XLPE-CWS Copper Conductors

Adobe Pfisterer Inner Cone Plug Terminations - Benefits for GIS and Switchgear

Adobe Gas Insulated SF6 Switchgear for High Voltage Substations - An Overview

Adobe ABB Gas Insulated Switchgear ELK-04 up to 170kV