Coba Switch Insulating Switchgear Matting For High Voltage Substations

By Chris Dodds on 9th October, 2014

Follow us on LinkedIn

Coba Switch Insulating Switchgear Matting For High Voltage Substations

COBA Switchboard Matting - CobaSwitch.

Who Are COBA?

Established in 1966 as COBA Plastics, the company was originally run by the two founders from a very small premises in central England.

Today COBA employs over 700 people with their matting and flooring products being used the world over. 

COBASwitch insulating matting provides high voltage insulation to substations, switchgear and switchrooms - COBASwitch matting protects against electrical shock for 11kV and 15kV switchgear installations. COBASwitch electrical insulating matting provides excellent resistance to transformer and switchgear oils and is fully independently tested to IEC 61111. Test report available on request.

Pictured: COBA Switch Insulating Switchgear Matting High Voltage 11kV 15kV

Coba Switch Insulating Switchgear Matting High Voltage 11kV 15kV

COBA Switchboard Matting Product Benefits

  • Provides safety for operative’s against electrical shocks
  • Designed for use in front of switchboards and high voltage equipment
  • Fine fluted surface provides slip-resistance
  • Available in two thicknesses: 4mm and 5mm
  • 4mm matting tested to 20kV for 30kV electrical working according to BS EN 61111 Class 2
  • 5mm matting tested to 40kV for 50kV electrical working according to BS EN 61111 Class 4 
  • BS EN 61111 insulating matting supercedes BS921/1976 specification 

 

IEC Classification System Against Maximum Working Voltages

Class AC Maximum Working Voltage For Matting 
0 1000V (1kV)
1 7500V (7.5kV)
2 17000V (17kV)
3 26500V (26.5kV)
4 36000V (36kV)

 

BS 921 Standard Superceded By IEC 61111

The British Standard BS 921 that specifys the Specification of rubber insulating mats for electrical purposes, has been replaced by the IEC 61111 standard. This action has come into place as it was conflicting with the current UK national standard for electrical insulating matting BS EN 61111.

Pictured: COBA Switch Electrical Safety Matting 11kV - 15kV

Coba Switch Electrical Safety Matting 11kV - 15kV

Pictured : T&D Meeting 8th October 2014 with Chris Stanley (COBA Sales Director) and Ashley Knight (COBA Account Manager North). Photography by Natalie Lundie (T&D Social Media Leader). 

Coba Switch Switchboard Matting - Rubber Insulating

 

Flickr Set : Click Link To Visually Inspect COBA Switch Insulating Matting  

Coba Switch Insulating Switchgear Matting

 

Video ABB offers extensive retrofit solutions for Reyrolle LMT, LMS, LMR and LMRP switchgear with the latest vacuum or SF6 circuit breakers. Reyrolle LM panels retrofitted with the Internal Arc modifications increase operator safety at a fraction of the cost of a new switchboard with minimal downtime.

 
Video : Switchgear Explosion. An electrical engineer is hear shown "racking-in and racking out" high voltage substation circuit breakers and generating an arc flash blast. All high voltage substations should be fitted out with electrical insulating matting in accordance with IEC 61111, ASTM or VDE standards. 