Pfisterer Sicon High Voltage Mechanical Lugs 11kV-33kV

Pfisterer Sicon High Voltage Mechanical Lugs 11kV-33kVPfisterer Sicon Connectors

Pfisterer Sicon High Voltage Mechanical Lugs 11kV-33kV

 

Pfisterer Sicon mechanical shearbolt lugs are used to terminate high voltage cable conductors, stranded copper or solid aluminium, prior to installing heat shrink or cold shrink cable terminations.

The Pfisterer Sicon shearbolt cable lugs and connectors have revolutionised the way shearbolt connectors11kV 33kVoperate. Conventional shearbolts have several pre-determined steps for shear points. The Sicon cable terminating system is stepless. Shearing occurs flush with the surface of the connector, so filling or filing is no longer necessary. A standard hex allen key is used for tightening so no special tools are needed for low and high voltage cable connecting and terminating without resort to crimping tools. 

Pictured : Pfisterer Sicon - Mechanical Shearbolt Cable Lugs & Connectors

Pfisterer Sicon Mechanical Lugs 11kV-33kV

 

Pfisterer Sicon Mechanical Shearbolt Cable Lugs - Features

  • Large range taking shearbolt bolt cable lugs
  • Cable lugs suitable for terminating low voltage and high voltage cable
  • Shearbolt cable lugs require no crimping tools or die sets 
  • Suitable for connecting copper and aluminium conductors
  • Blind hole designed as pressure-resistant oil barrier for oil filled cables
  • Suitable for Cold Shrink and Heat Shrink cable terminations
  • Suitable for terminating fine stranded class 5 cables
  • Smooth breaking shear bolt cable lugs simplifies installation
  • Suitable for use with 3M Cold Shrink cable joints and cable terminations

 

Installation of High Voltage Mechanical Shearbolt Cable Lugs

  • Strip the high voltage cable insulation for the distance specified in the cable jointing procedure.
  • With HV copper cable conductors, it may be necessary to wrap them with brass gauze.
  • With HV solid shaped aluminium conductors, it may be necessary to straighten or twist the core using special cable core twisting tools before inserting them into the connector. Wen tightening/shearing the bolts the HV connector can be held with an insulated holding tool.
  • To prevent HV cable core bending and damage to the insulation whilst shearing the bolts, always hold the body of the connector with a grip device before shearing the bolts.
  • On completion of the connector installation, recover all the sheared off bolt heads and count them to check that the number of heads recovered is the same as the number of bolts fitted. This ensures that the cable jointer has not trapped bolt heads, for example inside the insulation tubes. Check that all bolts have sheared correctly, at or just below the surface of the connector.

 

Video: Pfisterer Sicon High Voltage Mechanical Lugs 11kV-33kV

 
Video : Pfisterer Sicon - Shearbolt Cable Lugs & Connectors

Adobe HV Mechanical Shearbolt Lugs - 10-95mm2 M12 - 332/604/010

Adobe HV Mechanical Shearbolt Lugs - 25-150mm2 M12 - 332/599/010

Adobe HV Mechanical Shearbolt Lugs - 50-185mm2 M16 - 332/595/011

Adobe HV Mechanical Shearbolt Lugs - 50-240mm2 M12 - 332/595/010

Adobe HV Mechanical Shearbolt Lugs - 95-300mm2 M12 - 332/605/010

Adobe HV Mechanical Shearbolt Lugs - 95-300mm2 M16 - 332/605/011

Adobe HV Mechanical Shearbolt Lugs - 185-400mm2 M12 - 332/625/010

Adobe HV Mechanical Shearbolt Lugs - 185-400mm2 M16 - 332/625/011

Adobe HV Mechanical Shearbolt Lugs - 300-630mm2 M12 - 332/606/010