Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Cable

Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Cable

Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Cable

Flame Retardant Halogen-Free Medium Voltage 

Braided TFOI 6/10(12) kV

XLPE/EPR/TCWB/PO 

Prysmian Draka Offshore Drilling Cables

 

Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Application

Prysmian Draka Shipline TFOI 6/10(12)kV MV Power cables are armoured cable for fixed installation in ships where cable protection is required. The Shipline TFOI cable has medium Voltage power distribution. Prysmian Draka Shipline TFOI cable can be installed and operated both indoors and outdoors. Shipline TFOI cable has an operating temperature of 90°C and an operating voltage of 6/10(12)kV.Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Application

 

Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Approvals

  • Design - IEC 60092-354
  • Conductor - IEC 60228 class 2
  • Insulation - IEC 60092-351
  • Sheath - IEC 60092-359
  • Flame Retardant - IEC 60332-1
  • Flame Retardant - IEC 60332-3-22
  • Halogen Free - IEC 600754-1,2
  • Low Smoke - IEC 61034-1,2

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - Shipline TFOI 6/10(12)kV MV Power Construction

Conductor - Annealed stranded circular copper, IEC 60228 class 2

Conductor screen semiconductive - Extruded semiconductive layer

Insulation - Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)

Insulation screen semicoductive - Extruded semiconductive layer. A copper tape is applied as a metallic screen above the insulation screen. The thickness of the copper tape is 0,1 mm.

Lay up / Shielding - Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.

Inner covering - Flame retardant and halogen-free thermoplastic compound

Tape over bedding - Additional tape may be applied

Armour/screen - Tinned copper wire braid

Tape over armour/screen - Additional tape may be applied

Outer sheath - Flame retardant halogen-free thermoplastic compound, SHF1

Marking text - E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50 mm2 IEC 60332-3-22 ShipLine

Outer sheath colour - Red

 

T&D supply the complete range of Prysmian cable glands, cable cleats and cable joints suitable for industrial and hazardous area LV, MV & HV cable installations - this includes FP Fire Resistant cables.