Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation Cable

Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation Cable

Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation 

Flame Retardant Halogen-Free Instrumentation Cable

Mud resistant RU(i) 250V EPR/EVA

NEK 606 CodeS11

Prysmian Draka Offshore Drilling Cables

 

Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation Cable Application

Prysmian Draka RU(i) 250V S11 Unarmoured Instrumentation cable has fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas. RU(i) 250V S11 Unarmoured Instrumentation cable meets the mud resistant requirements in NEK 606. Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation Cable Application

 

Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation Cable Approvals

  • IEC 60092-376 (2003-05) - Design
  • IEC 60228 class 2 - Conductor
  • IEC 60092-351 - Insulation
  • IEC 60092-359 - Sheath
  • IEC 60332-1 - Flame Retardant
  • IEC 60332-3-22 - Flame Retardant
  • IEC 600754-1,2 - Halogen Free
  • IEC 61034-1,2 - Low Smoke

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - RU(i) 250V S11 Unarmoured Instrumentation Cable Construction

  1. Conductor - Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
  2. Insulation - EP-rubber, IEC 60092-351 (EPR)
  3. Pair / Triple / Quad Twisting - Colour coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbers printed directly on the insulated conductors.
  4. Lay up /Shielding - Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape.
  5. Inner Covering - No inner covering. (Additional tapes may be applied)
  6. Armour/Screen - No armour.
  7. Outer Sheath - Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)
  8. Marking Text - E.g. "meter" "year" DRAKA NORSK KABEL RU(i) 250V S11 2 pair 0,75 mm2 IEC 60092-376 IEC 60332-3-22
  9. Outer Sheath Colour - Grey or Blue

 

T&D supply the complete range of Prysmian cable glands, cable cleats and cable joints suitable for industrial and hazardous area LV, MV & HV cable installations - this includes FP Fire Resistant cables.

Prysmian Cable Joints Glands Cleats

UK Time - GMT: