Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication Cable

Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication Cable

Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication 

Individually Shielded and Isolated

HXXM EEP 0.6/1 kV IEC 60092-3

Prysmian Draka Offshore Drilling Cables 

 

Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication Cable Application

Prysmian Draka HXXM EEP 0.6/1KV Instrumentation & Communication cables are unarmoured, individually shielded and isolated instrumentation and communication cables 0.6/1 kV with special properties for electrical installations in ships and offshore units.

 HXXM EEP 0.6/1KV instrumentation and communication cable properties: Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, Halogen Free, Low Toxicity.

Prysmian Draka HXXM EEP 0.6/1KV instrumentation and communication cables are suitable for application in cold climate areas required to pass cold bend and cold impact testing at –40 °C and –35 °C, respectively.Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication Cable Application

 

Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication Cable Approvals

  • Fire propagation: IEC 60332-3 category “A”, “A/F”
  • Smoke: IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and NES 711
  • Acidity: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)
  • Halogen content: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)
  • Toxicity index: NES 713
  • Cold properties: cold bend (–40 °C) and cold impact (–35 °C) according to CAN/CSA-C22.2 No. 0.3-Dec. ’92
  • Remark: Other constructions available on request

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - HXXM EEP 0.6/1KV Instrumentation & Communication Cable Construction

  1. According to IEC 60092-3 with enhanced properties
  2. Conductors: stranded bare annealed copper, IEC 60228, sizes 1 - 4 mm2
  3. Insulation: cross linked polyethylene (XLPE/ HF XLPE) according to IEC 60092-3, IEC 60092-351 and IEEE Std 45
  4. Twisting: cores twisted to a pair/triad
  5. Individual Shield and Isolation: Tinned copper drain wire; aluminum/polyester tape; polyester tape
  6. Assembly: shielded pairs/triads cabled together
  7. Sheathing: halogen free, flame retardant (SHF1, IEC 60092-359); all sheath and jacketing materials shall pass tear resistance testing to 35 lbs/in (6.4 N/mm)
  8. Sheathing Colour: Grey (other colors are available on request)

T&D supply the complete range of Prysmian cable glands, cable cleats and cable joints suitable for industrial and hazardous area LV, MV & HV cable installations - this includes FP Fire Resistant cables.

Prysmian Cable Joints Glands Cleats

UK Time - GMT: