Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control Cable

Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control Cable

Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control 

Prysmian Draka Power and Control Armoured Cables

HXXMB EEP 0.6/1 kV IEC 60092-3 Class 5 conductors

Prysmian Draka Offshore Drilling Cables 

 

Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control Cable Application

Prysmian Draka Cables - HXXM CL5 cables are armoured power and control cables 0.6/1 kV with special properties for electrical installations in ships and offshore units. HXXM CL5 0.6/1kV Power & Control cable properties: Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, Halogen Free, Low Toxicity. Prysmian Draka HXXM CL5 0.6/1kV Power & Control cables are suitable for application in cold climate areas required to pass cold bent and cold impact testing at –40 °C and –35 °C, respectively.Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control Cable Application

 

Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control Cable Approvals

  • Fire propagation: IEC 60332-3 category “A”, “A/F”
  • Smoke: IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and NES 711
  • Acidity: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)
  • Halogen content: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)
  • Toxicity index: NES 713
  • Cold properties: cold bend (–40 °C) and cold impact (–35 °C) according to CAN/CSA-C22.2 No. 0.3-Dec. ’92

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - HXXM CL5 0.6/1kV Power & Control Cable Construction

Generally according to IEC 60092-3 0.6/1 kV

  1. Conductors: flexible bare annealed copper, IEC 60228, (Class 5) sizes 1 - 300 mm2
  2. Insulation: cross linked polyethylene (XLPE/ HF XLPE) according to IEC 60092-3, IEC 60092-351 and IEEE Std 45
  3. Assembly: cores cabled together
  4. Filler: halogen free filling compound
  5. Innersheath: halogen free, flame retardant (SHF1, IEC 60092-359)
  6. Braiding: bronze wire according to IEEE Std 45, CDA 220, weight coverage 90% on nominal diameter according to IEC 60092-3, wire diameter 0.32 - 0.40 mm
  7. Sheathing: halogen free, flame retardant (SHF1, IEC 60092-359); all sheath and jacketing materials shall pass tear resistance testing to 35 lbs/in (6.4 N/mm)
  8. Sheathing colour: gray (other colors are available on request)

 

 

T&D supply the complete range of Prysmian cable glands, cable cleats and cable joints suitable for industrial and hazardous area LV, MV & HV cable installations - this includes FP Fire Resistant cables.

Prysmian Cable Joints Glands Cleats

UK Time - GMT: