Prysmian Draka Cables - RFOU-HCF 6kV 10kV 12 kV P30/ 1100°C/ 30-60 minutes Cable

Prysmian Draka Cables - RFOU-HCF 6kV 10kV 12 kV P30/ 1100°C/ 30-60 minutes Cable

Prysmian Draka Cables - RFOU-HCF 6 10 12 kV P30/ 1100°C/ 30-60 minutes 

HydroCarbon Fire Resistant, Flame Retardant Halogen-Free Medium Voltage Power Cable.

RFOU-HCF 6/10(12)kV EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code P30

Prysmian Draka Offshore Drilling Cables

 

Prysmian Draka Cables - RFOU-HCF 6kV 10kV 12 kV P30/ 1100°C/ 30-60 minutes Applications

Prysmian Draka RFOU-HCF 6kV 10kV 12 kV P30/ 1100°C/ 30-60 minutes cable has fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital. Prysmian Draka Cables - RFOU-HCF 6kV 10kV 12 kV P30/ 1100C/ 30-60 minutes Applications

 

 

Prysmian Draka Cables - RFOU-HCF 6kV 10kV 12 kV P30/ 1100°C/ 30-60 minutes Approvals

  • IEC 60092-354 - Design
  • Draka Norsk Kabel - HCF protection
  • IEC 60228 class 2 - Conductor
  • IEC 60092-351 - Insulation
  • IEC 60092-359 - Sheath
  • IEC 60332-1 - Flame Retardant
  • IEC 60332-3-22 - Flame Retardant
  • IEC 60331-21 - Fire Resistant
  • UL 1709 / ASTM E1529 - HC Fire resistance
  • IEC 600754-1,2 - Halogen Free
  • IEC 61034-1,2 - Low Smoke

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - RFOU-HCF 6kV 10kV 12 kV P30/ 1100°C/ 30-60 minutes Construction

  1. Conductor - Tinned stranded and compressed copper (STCC), IEC 60228 class 2
  2. Conductor Screen Semiconductive -Semiconductive layer (EP-rubber)
  3. Insulation - R EP-rubber, IEC 60092-351 (EPR)
  4. Insulation Screen Semicoductive - Semiconductive layer (EP-rubber)
  5. Lay up / Shielding - Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.
  6. Inner Covering - Flame retardant and halogen-free thermoset compound
  7. Tape Over Bedding - PET tape
  8. Armour/Screen - Tinned copper wire braid
  9. Tape Over Armour/Screen - PET tape
  10. Outer Sheath - Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

T&D supply the complete range of Prysmian cable glands, cable cleats and cable joints suitable for industrial and hazardous area LV, MV & HV cable installations - this includes FP Fire Resistant cables.

Prysmian Cable Joints Glands Cleats

UK Time - GMT: