Prysmian Draka Cables - BU(c) 250V S14 Instrumentation Unarmoured Cable

Prysmian Draka Cables - BU(c) 250V S14 Instrumentation Unarmoured Cable

Prysmian Draka Cables - BU(c) 250V S14 Instrumentation Unarmoured 

Fire Resistant, Flame Retardant Halogen Free Power Cable

Mud Resistant BU(c) 250V MGT/EPR/EVA

NEK 606 CodeS14

Prysmian Draka Offshore Drilling Cables

 

Prysmian Draka Cables - BU(c) 250V S14 Instrumentation Unarmoured Cable Application

Prysmian Draka BU(c) 250V S14 Instrumentation unarmoured cable has fixed installation for instrumentation, communication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists.

BU(c) 250V S14 Instrumentation unarmoured cable meets the mud resistant requirements in NEK 606.

Prysmian Draka Cables - BU(c) 250V S14 Instrumentation Unarmoured Cable Approvals

  • IEC 60092-376 (2003-05) - Design
  • IEC 60228 class 2 - Conductor
  • IEC 60092-351 - Insulation
  • IEC 60092-359 - Sheath
  • IEC 60332-1 - Flame Retardant
  • IEC 60332-3-22 - Flame Retardant
  • IEC 60331-21 - Fire Resistant
  • IEC 600754-1,2 - Halogen Free
  • IEC 61034-1,2 - Low Smoke

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - BU(c) 250V S14 Instrumentation Unarmoured Cable Construction

  1. Conductor - Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
  2. Insulation - B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
  3. Pair / Triple / Quad Twisting - Colour coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
  4. Inner Covering - No inner covering. (Additional tapes may be applied)
  5. Armour/Screen - No armour
  6. Outer Sheath - Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)
  7. Marking Text - "meter" "år" DRAKA NORSK KABEL BU(c) 250V S14 8 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22
  8. Outer Sheath Colour - Grey or Blue

 

 