Prysmian Draka Cables - BFOU-HCF(i ) 250V S15/1100°C/30 minutes Instrument Cable

Prysmian Draka Cables - BFOU-HCF(i ) 250V S15/1100°C/30 minutes Instrument Cable

Prysmian Draka BFOU-HCF(i ) 250V S15/1100°C/30 minutes Instrument

HydroCarbon Fire Resistant, Flame Retardant Halogen-Free Instrumentation

BFOU-HCF(i) 250V MGT/EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code S15

Prysmian Draka Offshore Drilling Cables

 

Prysmian Draka Cables - BFOU-HCF(i ) 250V S15/1100°C/30 minutes Instrument Cable Application

Prysmian Draka BFOU-HCF(i) 250V S15 / 1100°C / 30 minutes Instrument cable has fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital. Prysmian Draka Cables - BFOU-HCF(i ) 250V S15/1100C/30 minutes Instrument Cable Application

 

Prysmian Draka Cables - BFOU-HCF(i ) 250V S15/1100°C/30 minutes Instrument Cable Approvals

  • IEC 60092-376 (2003-05) - Design
  • Draka Norsk Kabel - HCF protection
  • IEC 60228 class 2 - Conductor
  • IEC 60092-351 - Insulation
  • IEC 60092-359 - Sheath
  • IEC 60332-1 - Flame Retardant
  • IEC 60332-3-22 - Flame Retardant
  • IEC 60331-21 - Fire Resistant
  • UL 1709 / ASTM E1529 - HC Fire resistance
  • IEC 600754-1,2 - Halogen Free
  • IEC 61034-1,2 - Low Smoke

T&D distribute Prysmian Draka marine and offshore cables with Lloyds Register, DNV GL and NEK 606 standards. 

Prysmian

Prysmian Draka Cables - BFOU-HCF(i ) 250V S15/1100°C/30 minutes Instrument Cable Construction

  1. Conductor - Tinned stranded circular copper, IEC 60228 class 2
  2. Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
  3. Pair / Triple /Quad Twisting -  Colour coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors
  4. Inner covering - Flame retardant and halogen-free thermoplastic compound
  5. Tape Over Bedding - PET tape
  6. Armour/Screen - Tinned copper wire braid
  7. Tape Over Armour/Screen - PET tape
  8. Outer Sheath - Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)
  9. HCF protection -HCF Extruded heatblock compound
  10. Tape - Lapped glassfibre tape

T&D supply the complete range of Prysmian cable glands, cable cleats and cable joints suitable for industrial and hazardous area LV, MV & HV cable installations - this includes FP Fire Resistant cables.

Prysmian Cable Joints Glands Cleats

UK Time - GMT: