Wolf Airlamps - Hazardous Area ATEX Zone 1 & Zone 2
Wolf Turbolites - A-TL Range
Hazardous Area Zone 1 & Zone 2
Airlamps
Wolf Turbolite are airlamps for safe use in hazardous area Zones 1 & 2 and potentially explosive atmosphere - offering suitable lighting alternative solution to low voltage lighting in wet conditions
The Wolf Turbolites provide illumination for applications such as tank cleaning and pipeline inspections, commonly within the oil and petrochemical industries and are a safer alternative to mains and low voltage lighting in potentially explosive atmospheres.
Turbolites are available with either a bay light fitting which uses a ball glass and a protective polycarbonate dome to provide 360º illumination or with a reflector head fitting for direct illumination with either a polished or matt reflector for a concentrated narrow beam or a diffused wide angle beam.
Wolf's Turbolite's use a 24V 250W tungsten halogen bulb either providing 6,000 lumens for 2,000 hours or 9,000 lumens for 200 hours.
Pictured: Wolf Turbolites
Wolf Turbolites - Features & Benefits
Airlamp
Zones 1 & 2 Hazardous Areas
Wolf Product Reference | A-TL44 | A-TL45 | ||
Product Description | Safety Bay Light, Compressed Air Powered | Safety Flood Light, Compressed Air Powered | ||
Code | Ex s II T4 | |||
Apparatus Standards | SFA 3009:1972 | |||
Type of Protection | "s" Special Protection | |||
Area of Classification (Gas) | Zones 1 and 2, Gas Groups IIA, IIB, IIC | |||
Temperature Classification (Gas) | T4 | |||
Ambient Temperature | -20ºC to +40ºC | |||
Certificate | BASEEFA Ex 78209X* | |||
Enclosure | Nickel Plated Brass and Gun Metal | |||
Lens | Ball Glass / Polycarbonate Dome | Toughened Glass (15mm) | ||
Beam Type | All-around 360º Illumination | Flood (Matt Reflector as standard) or Spot (Polished Reflector to order) | ||
Light Source | Part Number | A-129 (as standard) / A-159 (alternative) | ||
Type | Halogen Filled Filament Bulb | |||
Volts | 24V | |||
Watts | 250W | |||
Output | 6000 lm / 9000 lm | |||
Life | 2,000 hours / 200 hours | |||
Power Source | Type | Compressed Air Driven Turbo-alternator | ||
Air Pressure | 4.0-8.0 bar | |||
Consumption | 0.75m³/min | |||
Ingress Protection | Once pressurised may be used underwater | |||
Weight | 7.9kg | 12.2kg | ||
*Special Certification Conditions | A clean dry air supply must be used. Supply hose must be anti-static |