Wolf's Flameproof Leadlamps are a lightweight portable floodlight which is ATEX certified for safe use in hazardous area Zones 1 & 2 and potentially explosive atmospheres where a T3/T4 temperature class permits.Wolf

The Wolf flameproof leadlamps are comprised of three different versions with the option of powering from a 12, 24 or 42V supply. The bulb ratings of each type of leadlamp vary from 55 to 70W and all offer unparalleled light output over an extremely wide 100º solid cone of light making it ideal for confined space applications.

Flameproof leadlamps are ideal for use in a wide range of potentially explosive atmosphere applications including cleaning, grit blasting and painting operations in tanks, silos and pipelines.

Wolf ATEX Flameproof Leadlamp - Zone 1 & Zone 2 Hazardous Area

Wolf ATEX Flameproof Leadlamp - Zone 1 & Zone 2 Hazardous Area

Wolf's flameproof lead lamps are constructed from die cast alluminium alloy making them lightweight and portable and easy to carry. A flameproof enclosure houses the halogen bulb, switch and connecting wires and a flameproof threaded joint allows internal access which allows for bulb replacement and maintenance.

A large rubber moulded guard surrounded the glass lend and flameproof threaded joint from impact damage.

Pictured: Wolf Flameproof Leadlamps ATEX

Wolf Flameproof Leadlamps ATEX

Wolf Flameproof Leadlamps ATEX - Features & Benefits

  • Complies with ATEX Directive. 94/9/EC
  • High output halogen light, up to 70 wattsWolf Safety
  • Lightweight alloy construction for single handed portability
  • Zone 1 & 2, Gas group IIC T3/T4 certified
  • Designed for quick and easy re-lamping and maintenanceATEX
  • 12, 24 or 42 Volts models available
  • Integral operation switch
  • Oil resistant rubber guard for drop and impact protection
  • Ideal for cleaning, grit blasting and painting operations

ATEX Certified Leadlamp

Zones 1 & 2 Hazardous Areas

  • Zone 1 & Zone 2 Gas
  • See below table for ATEX Certification details including T-Rating, Gas Groups and Zone locations
Wolf Flameproof Leadlamps ATEX - Product Range
Wolf Product Reference LL-12 LL-24 LL-42
Product Designation KHLE 70 EN
Product Description High Power Halogen Floodlight Leadlamp
Code II 2 G EEx d e IIC T3/T4
Equipment Category 2G
Type of Protection "d" flameproof, "e" increased safety
Area of Classification (Gas) Zones 1 and 2, Gas Groups IIA, IIB, IIC
Temperature Classification T4 T3
Ambient Temperature -20ºC to +40ºC
Certificate BVS 03 ATEX E 279
Enclosure Light Alloy, High Impact Plastic, Oil Resistant Rubber
Lens Toughened Glass
Light Source Part Number LL-230 LL-232 LL-234
Type Halogen Filled Filament Bulb
Volts 12V 24V 42V
Watts 55W 70W 65W
Beam 100º Wide Angle Flood
Life Up to 1000 hours
Power Source Insulation Class III
Voltage 12 Vac/dc 24 Vac/dc 42 Vac/dc
Ingress Protection IP54 minimum
Weight 2.5kg (excluding cable)

Wolf ATEX Flameproof Leadlamp - Product Dimensions

Wolf ATEX Flameproof Leadlamp - Product Dimensions

Pictured: Wolf Flameproof Leadlamps ATEX for Hazardous Areas Zone 1 & Zone 2

Wolf Flameproof Leadlamps ATEX for Hazardous Areas Zone 1 & Zone 2

Adobe

Wolf Flameproof Leadlamps ATEX - Instructions

Adobe

Wolf Flameproof Leadlamps ATEX - Spec Sheet

UK Time - GMT: