Wolf A-TL45A ATEX Turbolites Hazardous Area Zone 1 & Zone 2

Wolf A-TL45A ATEX Turbolites Hazardous Area Zone 1 & Zone 2

Wolf ATEX Turbolites

Wolf A-TL45A

Hazardous Area Zone 1 & Zone 2

ATEX Airlamps

 

Manufacturer: Wolf 

Part Code: A-TL45A

  • Description: Safety Flood Light, Compressed Air Powered
  • Hazardous Area Code:  II 2 GD II T4 (Tamb = 55°C) T135°C
  • Type Of Protection: Technical File
  • Hazardous Area Classification (Gas): Zones 1 and 2, Gas Groups IIA, IIB, IIC
  • Temperature Classification (Gas): T4
  • Hazardous Area Classification (Dust): Zone 21 and 22
  • Max Surface Temperature (Dust): T135°C
  • Ambient Temperature: -20°C to +40°C
  • Certificate: SIRA02ATEX5099X
  • Enclosure: Aluminium
  • Lens: Toughened Glass (15mm)
  • Beam Type: Flood (as standard) or Spot (to order)

Wolf A-TL45A ATEX Turbolites Hazardous Area Zone 1 & Zone 2

Wolf A-TL45A ATEX Turbolites Hazardous Area Zone 1 & Zone 2 - Features & Benefits

  • CE marked to ATEX Directive, for use in zones 1 and 2 Hazardous Areas
  • Aluminium super-lightweight constructionWolf Safety
  • 250 watt Halogen light output
  • Safe compressed air power source
  • Re-designed for greater reliability
  • Fitted with stainless steel exhaust silencerATEX
  • Dust ignition protected for zones 21 and 22 using remote exhaust
  • Group I Mining approval with alternative brass construction
  • US Factory Mutual dual marking approval
Wolf A-TL45A ATEX Turbolites Hazardous Area Zone 1 & Zone 2 - Technical Specification
Wolf Product Reference A-TL45A
Product Description Safety Flood Light, Compressed Air Powered
Code ATEX II 2 GD II T4 (Tamb = 55ºC) T135ºC
Mining -
FM Class 1 Div 1 Groups A, B, C, D, T4 Ta = 55ºC
Apparatus Standards EN1127:1998
Type of Protection Technical File
Area of Classification (Gas) Zones 1 and 2, Gas Groups IIA, IIB, IIC
Temperature Classification (Gas) T4
Area of Classification (Dust) Zones 21 and 22
Max Surface Temperature (Dust) T135ºC
Ambient Temperature -20ºC to +40ºC
Certificate SIRA02ATEX5099X
Enclosure Aluminium
Lens Toughened Glass (15mm)
Beam Type Flood (as standard) or Spot (to order)
Light Source Part Number A-129 (as standard) / A-159 (alternative)
Type Halogen Filled Filament Bulb
Volts 24V
Watts 250W
Output 6000 lm / 9000 lm
Life 2,000 hours / 200 hours
Power Source Type Compressed Air Driven Turbo-alternator
Air Pressure 5.0-8.0 bar
Consumption 0.75m³/min
Ingress Protection Once pressurised may be used underwater
Weight 7.1kg

 

Adobe

Wolf A-TL45A ATEX Turbolites Hazardous Area Zone 1 & Zone 2 - Spec Sheet

UK Time - GMT: