Cable Joints for Motorway Communications & Power Cables
Low Voltage LV Cable Joints & Cable Jointing Kits
Motorway Communications Cables
i) non-armoured copper communications cable to TR 2150
ii) non-armoured optical fibre communications cable to TR 2151
iii) non-armoured coaxial communications cable to TR 2152
iv) armoured copper communications cables to TR 2158
v) armoured composite copper/fibre optic cable to TR 2017
vi) armoured coaxial communications cables to TR 2160
vii) armoured feeder cables for inductive loop detectors to TR 2031
viii) inductive loop detector cable to TR 2029
Power Cables
i) non armoured energy cables to TR 2153
ii) armoured energy cable to TR 2161
It is recommended that cables shall be lubricated using a suitable water-based cable lubricant according to Series 1500.
Non-Armoured Cables - Installation to Series 1500
Draw cord should not be used for cable installation. The Contractor shall use the draw crod to pull through a purpose made cable pulling rope which shall then be used for cable installation. The cable pulling rope shall be attached to the cable by means of a pulling eye fitted to a stocking (copper and power cable) or a pulling eye attached to the central strength member (fibre cable). The Contractor should attach a swivel between the cable pulling rope and the pulling eye - purpose made bellmouths should be fitted to the exit and entry of every cable duct.
Armoured Cables - Installation to Series 1500
Cable marker tape shall be laid approximately 250mm above all communications and power cables - where several cables are laid in one trench one line of cable marker tape shall be installed for each 600mm of trench width.
T&D stock cable joints and cable gland terminations to suit all motorway comms and power cables.