Ellis Patents - Two Hole Plastic Cable Cleats - LSF & LSOH Cable Cleats

LSF LSOH Low Smoke Fume & Zero Halogen Cable Cleats

Ellis Patents Cable Cleats

Two Hole Plastic Cable Cleats

LSF & LSOH Cable Cleats

 

 

Ellis Patents two hole plastic cable cleats are available in black polypropylene (B) or black flame retardant zero halogen phosphorus free nylon (LSF).

LSF (Low Smoke & Fume - Zero Halogen) and flame retardant (FR) cable cleats suit 10-57mm cable diameters with single bolt hole fixing. 

Electrical building services specifications increasingly specify BS6724 LSOH (Low Smoke Zero Halogen) power cables to be cleated with LSF cable cleats - Ellis Patents zero halogen and flame retardant cleats provide excellent flame retardancy service with very low emissions of toxic fumes and smoke.

Pictured: Ellis Patents - Two Hole Plastic Cable Cleats - LSF & LSOH Cable Cleats

Ellis Patents - Two Hole Plastic Cable Cleats - LSF & LSOH Cable Cleats

 

Ellis Patents 2F-07 2 Hole Cable Clamp Cleat 38-46mm
Part No Suffix Cable Dia Range (mm) Dimensions (mm) Fixing Hole (mm) Pack Qty Weight (g) 
H D P B LSF LUL
2F-07 B/LSF/LUL 38-46 92 60 54 68 2 x M10 25 73.0 91.0 119.0
2F-08 B/LSF/LUL 46-51 103 71 54 79 2 x M10 25 80.9 109.9 132.0
2F-09 B/LSF/LUL 51-57 103 76 54 79 2 x M10 25 95.0 119.0 155.0
2F-10 B/LSF/LUL 57-64 103 82 54 79 2 x M10 25 89.1 122.5 156.5
2F-11 B/LSF/LUL 64-70 130 89 54 106 2 x M10 15 116.0 157.3 189.0
2F-1200 B/LSF/LUL 70-76 103 95 54 106 2 x M10 15 124.0 167.3 202.0
2F-1201 B/LSF/LUL 76-83 103 100 54 106 2 x M10 10 126.0 170.0 205.0
2F-1202 B/LSF/LUL 83-90 130 108 54 106 2 x M10 10 128.0 172.0 208.0
2F-131 B/LSF/LUL 90-97 150 115 54 126 2 x M10 5 152.0 208.0 248.0
2F-132 B/LSF/LUL 97-105 150 122 54 126 2 x M10 5 156.0 208.0 254.0
2F-141 B/LSF/LUL 105-112 161 130 54 135 2 x M10 5 179.5 238.8 292.0
2F-142 B/LSF/LUL 112-120 169 138 54 143 2 x M10 5 193.5 261.0 315.4
2F-151 B/LSF/LUL 120-128 177 148 54 151 2 x M10 5 212.0 280.0 346.0
2F-152 B/LSF/LUL 128-135 185 158 54 158 2 x M10 5 228.5 304.4 372.4

 

Note - Cables and accessories rarely initiate fires, but they could be involved in them and can significantly increase the damage caused should they propagate the fire. Until recently the flame retarding of cables was achieved by the use of halogenated flame retardants which are effective fire suppressants, but which unfortunately produce dense smoke and corrosive acid gases when burned. These effects are highly undesirable in a fire, hindering evacuation and fire fighting, endangering life and causing corrosion damage to expensive and vital equipment. The terms Limited Fire Hazard (LFH), Low Smoke & Fume (LSF), Low Smoke Halogen Free (LSHF) and Low Smoke Zero Halogen (LSZH) (LS0H) are used as material descriptions and as industry trade marks.

LSF Cable Cleats & BS6724 Power Cable - Copper conductors, XLPE insulation, steel wire armour (SWA) with black Low Smoke Zero Halogen (LS0H) outer cable sheath. BS6724 is specified for the supply of low voltage (LV) mains electricity to power networks, underground cable systems (direct burial) and in cable ducting – suitable for both indoor and outdoor use. BS6724 Low Smoke Zero Halogen (LS0H) SWA Cable is frequently supplied to projects in public areas where fire, smoke emissions and toxic fumes could potentially threaten both lives and equipment. When exposed to fire, the LS0H cable sheath emits very low levels of smoke and non-toxic levels of halogen gas (typically under 0.5% HCl emission.)

 

Ellis Patents - Two Hole Plastic Cable Cleats - LSF & LSOH Cable Cleats

 

Adobe Ellis Patents - Two Hole Plastic Cable Cleats