CMP Zen B350 Insulated Brass Cable Glands (Load End)

CMP ZEN Insulated Cable GlandsHigh Voltage Cable Terminations (SWA) with

CMP Zen Insulated Cable Glands & Cast Integral Earth Lug

CMP Zen Glands - Protect Against Short Circuit Earth Fault Currents

CMP Zen B350 Insulated Brass Cable Glands (Load End)

 

CMP B350 Zen insulated brass cable glands are suitable for the cable termination of high voltage, copper tape sceened, SWA steel wire armoured cables - indoor and outdoor with IP66 seal.

 

CMP Zen Insulated Cable Glands - High Voltage Cable Termination with Brass or Aluminium Cable Glands
In the power generation industry unless special measures are taken to both segregate LV-HV cables in accordance with wiring regulations, and also isolate the metallic cable armour from running in continuous contact throughout the whole of the earthing system, interference or electrical noise would spread throughout the plant. CMP Zen Insulated cable gland system allows cables to be earthed at one end only - single point earthing - and insulated at the field end. Insulated Zen cable glands are available to ensure that no contact is made between the earth circuit carried through the cable armour and the low-high voltage electrical enclosure which the cable enters. CMP Zen Insulated cable glands permit electrical design engineers to implement safe earthing systems to deal with :

  • Cross Talk Noise Reduction
  • Electrical Separation of Main Earths
  • Earth Fault Segregation
  • Fault Current Reduction with Series Cable Resistance
  • Electrical Noise Reduction in Instrument Cables
  • Circulating Current Production in Single or 3 Core High Voltage Cables
     

CMP Zen B350 Insulated Brass Cable Glands

CMP Zen Insulated Cable Glands - CMP B327 & B350 Cable Glands HV
CMP Zen insulated cable glands are suitable for use with all steel wire armoured (SWA) cables providing an IP66 environmental seal on the cable outer sheath. CMP B327 Zen cable glands feature Cast Integral Earth Lug (CIEL) suitable for high voltage power cable systems where a high level of protection against fault currents is required - CMP's unique cable glanding concept effectively insulates the cable gland and cable armour from the electrical equipment eliminating circulating currents. CMP Zen B327 cable gland is usually installed at the supply end of the cable and Zen B350 cable gland at the load end. This cable gland system differs from the CMP Zen B324-B348 with the addtional feature of providing a termination facility for high voltage copper tape screen cable.

 

YouTube Video Playlist: CMP Cable Glands For Low Voltage Cable Termination

Adobe CMP Cable Glands - General Catalogue

Adobe CMP Zen B350 Insulated Brass Cable Glands 12.5-90.4mm