CMP A2F Hazardous Area Flameproof ATEX Cable Glands for Unarmoured Cables

CMP Cable Glands

ATEX Cable GlandsCMP Hazardous Area Flameproof ATEX Cable Glands

CMP A2F ATEX Cable Glands

Unarmoured & Braided Cables

Zone 1, Zone 2, Zone 21, Zone 22 Cable Glands

Hazardous Area Cable Glands

 

 

 

CMP A2F Flameproof (Type 'd'), Increased Safety (Type 'e') and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas.

CMP A2F hazardous area cable glands are suitable for terminating unarmoured cables.

CMP A2F hazardous area glands provide a combined flameproof seal and environmental seal on the cable outer sheath - CMP A2F cable glands provide full compatibility with restricted breathing equipment that rely upon flammable gases being excluded from the main enclosure.

Pictured : CMP A2F Hazardous Area Cable Gland

CMP A2F Hazardous Area Cable Glands

 

CMP A2F Tri-Star Hazardous Area Triple Certified Flameproof (Type 'd'), Increased Safety (Type 'e') and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured and braided cable providing a combined flameproof seal and environmental seal on the cable outer sheath.

CMP cable glands provide full compatibility with restricted breathing equipment for low voltage un-armoured cable terminations in hazardous areas with ATEX approved requirements. CMP A2F Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas.

CMP A2F Hazardous Area Cable Glands

  • Cable Gland Type : CMP A2F
  • Cable Gland Material : Brass, Nickel Plated Brass, Stainless Steel, Aluminium
  • Cable Type : Unarmoured & Braided
  • Ingress Protection : IP66, IP67, IP68
  • ATEX Certificate : SIRA13ATEX1068X, SIRA13ATEX4074X
  • IEC Ex Certificate : IECEx SIR 13.0023X

 

ATEX Code of ProtectionATEX

Ex II 2/3G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex IM2 Ex d I Mb, Ex e I Mb

 

IEC Ex Code of ProtectionIEC Ex

Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb

 