Scame ADVANCE GRP EX - ATEX Hazardous Area Zone 22 Socket (Interlocked-switch Socket Outlet)

Scame ADVANCE GRP EX - ATEX Hazardous Area Zone 22 Socket (Interlocked-switch Socket Outlet)

Scame Electrical Solutions

 

 

Scame Plugs & Sockets

ATEX Plugs & Sockets

Hazardous Area Zone 22

16A  32A  63A  125A

 

ADVANCE GRP EX - ATEX Hazardous Area Zone 22 Socket

Interlocked-switch Socket Outlets 

• EN 60309-1         
• EN 60309-2          • EN60309-4

• EN 61241-0         • EN 61241-1           Ex II 3D - Ex tD A22 IP66 T90°C

• Ta -25°C +60°C 

Scame GRP Sockets - Ex ATEX Hazardous Area

The ADVANCE GRP EX ATEX hazardous area Zone 22 socket outlets are suitable for installation into environments under potential risk of explosion identified as Zone 22 and that enter into the field of application for the ATEX Hazardous Area Directive (European Directive 94/9/CE).

ADVANCE GRP EX ATEX hazardous area Zone 22 socket outlets include a series of 16A, 32A, 63A, 125A interlocked sockets (compliant with EN60309-4 standards) and the casings to contain them.

ADVANCE GRP EX ATEX hazardous area Zone 22 socket outlet range is the most complete range of interlocked sockets produced in GRP (Glass Reinforced Polyester) thermosetting material.

ADVANCE GRP EX ATEX Hazardous Area Zone 22 Socket Outlet Versions:
The ADVANCE GRP hazardous area sockets also includes a series of 16A, 32A, 63A and 125A interlocked sockets for installation in environments with a potential risk of explosion identified as Zone 22 (dust) which fall under the area of application of the Atex Directive (European Directive 94/9/EC), compliant with the standards EN61241-0 and EN61241-1.

Type of protection : Ex II 3D - Ex tD A22 IP66 T90°C
Ta -25°C +60°C. 

ADVANCE GRP EX ATEX Hazardous Area Zone 22 Socket Outlets:

  • Sockets with mechanical interlock
  • Sockets with switch-disconnector
  • Sockets with switch-disconnector and fuse
  • 125A sockets with fuse and switch-disconnector
  • 125A sockets with molded case circuit breaker and thermal magnetic trip unit 
  • 125A sockets with molded case circuit breaker, thermal magnetic and residual current release trip units
ADVANCE GRP EX ATEX Hazardous Area Zone 22 Socket Specification

Rated Current

16A-32A-63A-125A

Rated Voltage

100÷690V~

Frequency

50hz÷60Hz

Insulating Voltage

500/690V~

Self-Extinguishing GW Test

960°C

Self-extinguishing UL94

V0
Switch-Disconnectors

16A-32A-63A COMMAND Series

125A Switch ABB OT 160

Fuse

16A-32A gG 10,3x38mm

63A gG 22x58mm

125A NH00

Colour

Grey RAL7037

ATEX Code

II 3D

Ex Protection Type

Ex tD A22 IP66 T90°C Ta -25°C +60°C

Operating Temperature (according to the reference standard)

-25°C +60°C

Maximum Permissible Surface Temperature

T90°C

Switched Socket Outlets With Interlock Degree Of Protection

IP66

Plugs - Degree Of Protection

IP66/IP67

Impact Resistance

IK10 (20J) - (24V 4J)

Switched Socket Outlets With Interlock Material

Thermosetting
Interlocked Switch Sockets Outlets CE Certified

16A-32A-63A SCAME ATEX 04

125A: SCAME ATEX 02

Plugs CE Certificate

SCAME ATEX 03


Industrial and ATEX Hazardous Area Zone 22 Socket Outlet Standards :

EN 60309-1
Plugs, socket-outlets and couplers for industrial purposes.
Part 1: General requirements.

EN 60309-2
Plugs, socket-outlets and couplers for industrial purposes.
Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonised configurations.

EN 60309-4
Plugs, socket-outlets and couplers for industrial purposes.
Part 4: Switched socket-outlets and connectors with or without interlock.

IEC 61241-0 / EN 61241-0
Electrical apparatus for use in the presence of combustible dust.
Part 0: General requirements.

IEC 61241-1 / EN 61241-1
Electrical apparatus for use in the presence of combustible dust.
Part 1: ATEX Ex Protection by enclosures \'tD\'.

Adobe

ADVANCE GRP EX - ATEX Hazardous Area Zone 22 Socket (Interlocked-switch Socket Outlet)