Petrel - Hazardous Area ATEX Zone 1 & Zone 2 Lighting

Petrel - Hazardous Area ATEX  Zone 1 & Zone 2 Lighting

Hazardous Area Lighting - Petrel
Zone 1 Hazardous Area Lighting
Zone 2 Hazardous Area LightingZone 1 Zone 2 Hazardous Area Lighting ATEX

Petrel hazardous area lighting ranges are suitable for Zone 1 and Zone 2 lighting installations with ATEX certification. Zone 1 Hazardous Area – a potentially explosive atmosphere where a mixture of air and flammable substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. 10 to 1000 hours/year. Zone 2 Hazardous Area - a potentially explosive atmosphere where a mixture of air and flammable substances in the form of gas, vapor or mist is unlikely to be present except for short time periods. Less than 10 hours/year. 
 

Hazardous Area Lighting - Zone 1 &  Zone 2 Lighting : Petrel Overview 
Zone 1 Lighting Hazardous Area ATEX Welllglass
Zone 1 Lighting Hazardous Area ATEX Standard Luminaires
Zone 1 Lighting Hazardous Area ATEX Emergency Luminaires
Zone 1 Lighting Hazardous Area ATEX Compact Luminaires 
Zone 1 Lighting Hazardous Area ATEX Floodlights 
Zone 1 Lighting Hazardous Area ATEX Standard Fluorescent Luminaire
Zone 1 Lighting Hazardous Area ATEX Emergency Fluorescent Luminaire 
Zone 1 Lighting Hazardous Area ATEX Luminaire (Recessed)
Zone 2 Lighting Hazardous Area ATEX Submersible Bulkhead Lighting 
Zone 2 Lighting Hazardous Area ATEX Bulkhead Lighting 
Zone 2 Lighting Hazardous Area ATEX Fluorescent Luminaire 
Zone 2 Lighting Hazardous Area ATEX Floodlights 


EN-60 598 2.22 Standard - Emergency Lighting for Hazardous Areas
The European product standard sets out the ATEX hazardous area requirements for materials, design, manufacture, testing and operation of hazardous area lighting luminaire equipment.

All Petrel ATEX hazardous area lighting luminaire equipment comply with EN 60 598 2.22 when used in an ambient temperature between 0 and +25ºC.

Types of ATEX Protection for Hazardous Area Lighting Systems
EEx ia EN/IEC 60079-11:
Intrinsic Safety, Zone 0, ATEX Cat 2 & 3
EExib EN/IEC 60079-11: Intrinsic Safety, Zone 1 & 2, ATEX Cat 2 & 3
EEx d EN/IEC 60079-1: Flameproof, Zone 1 & 2, ATEX Cat 2 & 3
EEx e EEN/IEC 60079-7: Increased Safety, Zone 1 & 2, ATEX Cat 2 & 3
EEx p EN/IEC 60079-2: Pressurised, Zone 1 & 2, ATEX Cat 2 & 3
EEx m EN/IEC 60079-18: Encapsulated, Zone 1 & 2, ATEX Cat 2 & 3
EEx q EN/IEC 60079-5: Powder Filled, Zone 1 & 2, ATEX Cat 2 & 3
EEx o EN/IEC 60079-6: Oil Filled, Zone 1 & 2, ATEX Cat 2 & 3
EEx N EN/IEC 60079-15: Non Sparking, Zone 2, ATEX Cat 3

EX Lighting Products from Petrel Hazardous Area Electrical Equipment : Ex de Well Glass, Ex d Emergency Fluorescent Luminaire, Ex de Bulkhead, Ex de Zone 1 Floodlight, Zone 2 Floodlight, Ex ed Standard & Emergency Fluorescent Luminaire, Zone 2 Standard & Emergency Fluorescent Luminaire, Ex d Fluorescent Luminaire, Zone 2 Bulkhead Luminaire, Ex ed Recessed Zone 1 Fluorescent Luminaire. Also : Petrel - Hazardous Area ATEX Zone 1 GRP Electrical Enclosures.

ATEX Certified Lighting for Hazardous Area Zones 1 & Zones 2
ATEX is the name given to a set of European Directives relating to Hazardous Area ElectricalZone 1 Zone 2 Hazardous Area Lighting ATEX Equipment Installations (Flammable Atmospheres), including lighting, to avoid industrial accident or incident. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers Electrical Equipment installed in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts - this includes  fluorescent, recessed, helideck, LED floodlight, bulkhead and well glass hazardous area lighting.

Thorne & Derrick UK are specialist Hazardous Area (ATEX) Electrical Equipment Distributors - we distribute Flameproof, Explosion Proof and Intrinsically Safe electrical equipment for Zone 1, 2, 21 and 22 hazardous areas. T&D UK service the global oil, gas, petrochemical, mining, offshore and marine industries with LV-HV hazardous area electrical equipment.

Petrel 457 Submersible Bulkhead - Petrel Hazardous Area (ATEX certified) Zone 2 Bulkhead Lighting 

Adobe

Petrel - ATEX Ex d & Ex de Hazardous Area Lighting, Enclosures & Starters Zone 1 Zone 2

Adobe

Petrel Hazardous Area Lighting (Zone 1 Zone 2) Catalogue

Adobe

Hadar Hazardous Area Lighting (Zone 1 Zone 2) Catalogue

Adobe

Victor Hazardous Area Lighting (Zone 1 Zone 2) Catalogue

UK Time - GMT: