Medium Voltage Cable Terminations 3 - Earthing

By Chris Dodds on 1st November, 2013

Follow us on LinkedIn

Medium Voltage Cable Terminations 3 - Earthing

 

 

 

In this series of 15 blogs we provide Chapter breakdowns for the Nexans published book, "Medium Voltage Cable Accessories, A Theoretical and Practical Approach".

We now overview Chapter 10: Medium Voltage Cable Terminations 3 - Earthing.

The book covers the installation of medium voltage cable terminations, separable connectors, cable joints and associated equipment such as cable glands and cable cleats.

Great emphasis is placed on failure modes and methods of preventing potential problems in service.

Essential reading for:

  • Lead Electrical Engineers
  • Electrical Project Engineers
  • Principal Electrical Engineers
  • Plant Engineers
  • LV HV EHV Cable Jointers
  • ATEX Inspectors
  • Substation Commissioning Managers
  • LV HV EHV Project Managers
  • Buyers & Procurement Managers
  • SAP's
  • Sales Managers & Engineers

The book is an instant hit with DNO's, IDNO'S, ICP's, MV HV Cable Jointers, Cable Contractors, Utility Cable Jointer Training Schools, Electrical Contractors and Substation Engineers.

Chapter 10: Medium Voltage Cable Terminations

3 Earthing - From Medium Voltage Cable Accessories

  • 10.1. Introduction
  • 10.2. Outdoor medium voltage cable terminations
  • 10.2.1. Single core medium voltage cable with copper wires or copper tape screen
  • 10.2.2. Single core medium voltage polymeric cable with aluminium armour
  • 10.2.3. Three core polymeric medium voltage cable with steel wire armour
  • 10.2.4. Three core medium voltage paper cable with corrugated aluminium sheath
  • 10.2.5. medium voltage paper cable with lead sheath and steel wire armours
  • 10.2.6. Three core medium voltage paper cable with steel tape armour
  • 10.3. Indoor medium voltage terminations
  • 10.3.1. Single core unarmoured MV polymeric cable
  • 10.3.2. Single core MV cable with tape screen and armours
  • 10.3.3. Three core MV paper cable with corrugated aluminium sheath
  • 10.3.4. Three core MV cable with steel wire armours
  • 10.4. Compression glands
  • 10.4.1. Ingress protection – IP ratings
  • 10.4.2. Gland seals
  • 10.4.3. Cable support
  • 10.4.4. Cable earthing

Medium Voltage Cable Accessories

Nexans (Euromold) manufacture high voltage Screened Separable Connectors (Elbow & Bolted Tee), Cable Joints & Cable Terminations (Cold Shrink & Heat Shrink), Bushings and Surge Arresters are available to suit 11kV, 33kV and up to 42kV distribution networks.

Medium Voltage Cable Accessories Book Published By Nexans

  • Nexans Cable Joints, Cable Terminations, Screened Separable Connectors - High VoltageFormat: Hardback
  • Extent: 160pp
  • Size: 300x215mm [Nexans 11kV 33kV Cable Jointers Book]
  • ISBN: 978-0-9573785-0-6
  • RRP: £79.99
  • Illustrations: Nexans Power Accessories (UK)
  • Publication Date: March 2013

Video Preview : Medium Voltage Cable Accessories Book Published By Nexans

Nexans Medium Voltage Cable Accessories Book - Content Pages

Adobe

Nexans Medium Voltage Cable Accessories Book





Category:  Nexans Euromold Cable Accessories

Go back to blog index