ABB Screened Separable Connectors for High Voltage Switchgear & Transformer Cable Terminations

ABB HV Cable Connectors - 11-24kV Screened Separable Connectors for Switchgear & Transformer Cable Terminations
Tested and Approved to CENELEC HD629.1  S2

ABB Screened Separable Connectors for High Voltage XLPE Cable Termination, 11kV-24kV-33kV.ABB High Voltage Switchgear & Transformer Cable Terminations

ABB HV cable connectors are premolded screened separable connectors for terminating and connecting XLPE insulated single or three core cables with copper or aluminium conductors, 11-24kV-33kV, into high voltage switchgear and transformers. ABB connectors terminate high voltage cables with copper wire and copper tape screens, with or without aluminium (AWA) or steel wire armour (SWA) inot switchgear and transformers.

ABB CSE-A (elbow connectors) and ABB CSS-A (straight connector) fits standard switchgear and transformer bushings of external cone type in accordance with EN 50181 fulfiling the requirements of CENELEC HD 629.1 S2.

ABB CSE-A 12250, 24250 and ABB CSS-A 12250, 24250 high voltage connectors fit standard switchgear and transformer bushings of the external outer cone type according to EN50181, 200 series 250A, plug-in 7.9mm diameter.

ABB CSE-A 12400, 24400 high voltage connectors fit standard switchgear and transformer bushings of the external outer cone type according to EN 50181, 400 series 400A, plug-in 14mm diameter.

ABB CSE-A 12630, 24630 high voltage connectors fit standard switchgear and transformer bushings of the external outer cone type according to EN 50181, 400 series 630A, M16 bolt.

ABB HV cable connectors are suitable for terminating high voltage XLPE insulated cables in both indoor and outdoor installations.

ABB HV Cable Connectors for Switchgear & Transformer Cable Terminations
ABB CSE-A and ABB CSS-A are manufactured in rubber with three layers - a conductive layer, an insulation layer and a conductive outer layer vulcanised together to provide optimum interface between the electrical layers. ABB HV cable connectors include a capacitive test point with protection and an integrated earthing wire.

*Fulfil touch-proof requirements for high voltage cable installations
*Suitable for high voltage cable terminating into switchgear or transformers
*3 phase kits complete with cable lugs, screw connection and stress kits
*No specialist high voltage jointing tools required
*Minimal cable stripping
*Compact HV connectors for contained switchgear/transformer terminations

ABB HV Cable Connectors - Discontinued Products Decemeber 2010
ABB SOC250 TP
ABB SOC250 STP
ABB SOC630-1
ABB SOC630-2
ABB SOC630-3
ABB SOC630-4
ABB SOC630-5
ABB SOC630-1 TP
ABB SOC630-2 TP
ABB SOC630-3 TP
ABB SOC630-4 TP
ABB SOC630-5 TP

ABB 2011 new product replacements :
ABB CSE-A replaces SOC and also SOC TP
ABB CSS-A replaces SOC STP

T&D stock and distribute an extensive range of High Voltage Cable Terminations, Plugs & Cable Connection Systems up to 33kV for polymeric (XLPE EPR) and paper (PILC) insulated cables - 3M Cold Shrink Terminations, Prysmian Heat Shrink Terminations, SPS Heat Shrink Terminations, Nexans Screened Separable Connectors and Pfisterer Inner Cone Plugs compatible with air and gas insulated switchgear manufactured by ABB, Siemens, Eaton Alstom, Brush, Schneider and Hawker Siddley. Electrical system designers and contractors should be attentive to the short circuit forces generated by high voltage power cables and select cable cleats to provide cable support and containment - Ellis Patents Cable Cleats provide reliable cleating of high voltage cables, 11-33kV.

 