CMP E1FW Hazardous Area Flameproof ATEX Cable Glands for Armoured Cables (SWA)

CMP Cable Glands

ATEX CertifiedCMP Hazardous Area Flameproof ATEX Cable Glands

CMP E1FW ATEX Cable Glands

Armoured Cables (SWA)

Zone 1, Zone 2, Zone 21, Zone 22 Cable Glands

CMP Hazardous Area Glands

CMP E1FW Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) cable glands for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with steel wire armoured (SWA) cable.

CMP E1FW cable glands provide a flameproof seal on the cable inner bedding and in addition the gas tight seal has been tested to prove compatibility with Restricted Breathing equipment.

CMP E1FW flameproof cable glands allow mechanical cable retention and earth continuity via the cable armour termination.

CMP E1FW cable glands are suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22.

Pictured: CMP E1FW Hazardous Area Cable Gland

CMP E1FW Cable Glands For Hazardous Area

Flameproof Ex "d" Cable Glands

Electrical equipment may include arcing and sparking (incendive) devices and flammable mixtures which may enter the enclosure or junction box. The CMP cable gland design is specified to contain an internal explosion and prevent transmission of sufficient energy to ignite a potentially flammable atmosphere outside the enclosure or junction box in hazardous areas.

Separate tightening actions for the inner displacement gland seal and the armour termination afford maximum control over the pressure applied to the cable bedding, and also allows the effectiveness of the gas tight seal to be tested. A detachable armour cone and CMP AnyWay clamping ring arrangement facilitates remote make off and enables the cable to be disconnected from the equipment.

An environmental / load retention seal is provided on the cable outer sheath. The CMP E1FW Tri-Star Cable Gland is suitable for use with all forms of hazardous area electrical equipment protection permitted in Zone 1, Zone 2, Zone 21 and Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.

 

CMP E1FW Hazardous Area Cable Glands

  • Cable Gland Type: CMP E1FW
  • Cable Gland Material: Brass, Nickel Plated Brass, Stainless Steel, Aluminium
  • Cable Type: Single Wire Armour (SWA), Aluminium Wire Armour (AWA)
  • Ingress Protection: IP66 (Standard), IP67 & IP68
  • ATEX Certificate: SIRA13ATEX1071X, SIRA13ATEX4077X
  • IEC Ex Certificate: IECEx SIR 13.0026X

ATEX Code Of Protection

Ex II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da, Ex II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb

 
ATEX
 

IEC Ex Code Of Protection 

Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb 

 

 

Pictured: CMP E1FW ATEX Cable Glands Installation Instructions

Hazardous Area Cable Glands E1FW

 

Pictured: CMP E1FW ATEX Cable Glands Installation. Pass the cable through the E1FW cable gland until the wire armour is engaged with the cone spreading the armour evenly around the cone.

Video: CMP Products - E1FW Cable Gland - Direct Make Off

Adobe CMP E1FW Cable Glands - Installation Instruction

Adobe CMP E1FW Hazardous Area Flameproof ATEX Cable Glands for Armoured Cables (SWA)