3M CR Control Cable Joints : Hazardous Area
Low Voltage Resin Cable Jointing & Splice Kits for Control Cables
3M Scotchcast CR hazardous area control cable joints are suitable for multi-core XLPE, EPR and PILC cables with steel wire armour (SWA) or galvanised steel wire braid (GSWB), 0.6/1kV and up to 3.3kV - 3M CR control cable joints are hydrocarbon resistant and flame retarded for Zone 1 and Zone 2 hazardous area installation.
3M CR Scotchcast cable joints are also suitable for lead sheathed (XLPE & PILC) control cables.
3M Scotchcast No. 1400U resin cable joints are flame retardant with excellent long term resistance against hydrocarbons - Scotchcast resin cable joints are suitable for areas where there is a danger of gas, oil, sewage or chemical spillage including Zones 1 & Zone 2 Hazardous Areas.
No. of Cable Cable Size
Cores Joint Kit min max
2 to 6 CR2 Cable Joint 14 32mm
7 to12 CR3 Cable Joint 23 37mm
14 to 21 CR4 Cable Joint 28 51mm
24 to 37 CR5 Cable Joint 33 60mm
3M Scotchcast resin cable joint kit CR range, has now been replaced by 3M Scotchcast LVI3-IC for flame retardant, hydro-carbon resistant, halogen-free resin cable jointing of multi-core or multi-paIr control and instrumentation cables in hazardous areas - 3M LVI cable joints are specified for Zone 1 and Zone cable jointing and also for underground direct burial applications in areas of high soil contamination.
3M Cable Joints for Hazardous Areas in relation to ATEX 94/9/EC Directive - The ATEX Directive covers a large range of electrical equipment, potentiallly including equipment used on fixed offshore platforms, in petrochemical plants, mines, flourmills and other areas where a potentially explosive atmosphere may be present. In very broad terms, there are three pre-conditions for the ATEX Directive to apply to electrical equipment certification : the equipment a) must have its own source of ignition b) be intended for use in a potentially explosive atmosphere (air mixtures) c) be under normal atmospheric conditions. When used as directed, 3M cable joints and cable terminations do not have a source of ignition. The firing of an explosive atmosphere may be caused by a short circuit, but when installed according to 3M instruction, these 3M cable joints and terminations are safe against short circuits. To conclude, 3M cable accessories (cable joints, terminations, abandonment kits) are not within the scope of the ATEX directive.
Control Cable Joints - Hazardous Areas - 3M CR2 - 2 to 6 Cores
Control Cable Joints - Hazardous Areas - 3M CR3 - 7 to 12 Cores
Control Cable Joints - Hazardous Areas - 3M CR4 - 14 to 21 Cores
Control Cable Joints - Hazardous Areas - 3M CR5 - 24 to 37 Cores
3M CR Control Cable Jointing Kits, CR2-CR5 (Hazardous Area) - JI
3M Hazardous Area LV Cable Joints & Cable Terminations - Catalogue
3M Hazardous Area Cable Joints, Zone 1 and 2 - ATEX Compliance
EEMUA Cable - BS6346 Lead Sheath Armoured (LC-SWA) - Nexans
Prysmian Control Cables for Petrochemical & Hydrocarbon Industries
Tratos Marine, Offshore Oil & Gas Cables (BS6883 & BS7917)
3M Electrical - Cable Joints, Terminations, Tapes, Heat Shrink, Cold Shrink Cable Accessories