3M COLD SHRINK CABLE JOINTS, CABLE TERMINATIONS & CABLE ABANDONMENT

3M Cold Shrink Cable Joints, Cable Terminations,  Cable Abandonment

3M Cold Shrink ……..There is no Equivalent

 

Modern 3M Cold Shrink technology has replaced traditional heat shrink as the specification standard for cable abandonment, jointing and terminating of LV-HV cables in the oil, gas, petrochemical, utility and construction industries.

3M Cold Shrink cable joints, terminations and abandonment kits offer faster, safer and simpler installations without the dangers and hassles of “hot-working” - no naked flames, no gas torches, no ignition tooling, no “hot-work” permit applications.

Instant Energisation - Minimised Power Interruptions
3M Cold Shrink joints and terminations allow immediate power restoration during utility fault work, unplanned outages or planned shutdowns – no “curing” or “cooling” delays associated with resin or heat shrink cable jointing.  

 

 

Adobe 3M Cold Shrink Joints, Terminations & Abandonment Kits - 2009 Prices

Adobe 3M Cold Shrink Tubes, Tubing, End Caps

Adobe 3M Cold Shrink - Life Begins at 40

3M COLD SHRINK CABLE JOINTS, CABLE TERMINATIONS & CABLE ABANDONMENT

3M Cold Shrink Cable Joints & Cable Terminations.


3M Cold Shrink cable joints and cable terminations are suitable for XLPE, EPR, PVC insulated cables with SWA, GSWB or lead sheath up to 3.3kV.

 

Selection guide for 3M Cold Shrink LC Series Cable Joints :

 

Nominal
Conductor
Area (mm²)
2
Core
1kv Cable Joint
3
Core
1kv Cable Joint
4
Core
1kv Cable Joint
3
Core
3.3kv Cable Joint
1.5 LC1 LC1 LC1 N/A
2.5 LC1 LC1 LC1 N/A
4 LC1 LC1 LC2 N/A
6 LC2 LC2 LC2 N/A
10 LC2 LC2 LC3 N/A
16 LC3 LC3 LC3 LC4
25 LC3 LC3 LC3 LC4
35 LC3 LC3 LC4 LC4
50 LC3 LC4 LC4 LC4
70 LC4 LC4 LC5 LC5
95 LC4 LC5 LC5 LC5
120 LC4 LC5 LC5 LC5
150 LC5 LC5 LC6 LC5
185 LC5 LC6 LC6 LC6
240 LC6 LC6 N/A LC6
300 LC6 N/A N/A N/

 

 

Selection guide for 3M Cold Shrink LCT Series Cable Terminations :

 

Nominal Conductor Area

Cold Shrink Termination 

Kit Ref

Accepted Cable Diamter over Lead Sheath (CFS) Accepted Cable Diamter over Insulation (PST)
    Max (mm) Max (mm) Max (mm) Max (mm)

35

50

LCT/1

LCT/1

23.5 37 16 33

70

95

120

LCT/2

LCT/2

LCT/2

31 50 16 33

150

185

LCT/3

LCT/3

44 70 19 40

240

300

400

LCT/4

LCT/4

LCT/4

TBA TBA TBA TBA

3M Cold Shrink Cable Joint - 16.2 to 33.1mm Dia - 3M LC1 Cable Joint

3M Cold Shrink Cable Joint - 16.2 to 33.1mm Dia - 3M LC2 Cable Joint

3M Cold Shrink Cable Joint - 16.2 to 33.1mm Dia - 3M LC3 Cable Joint

3M Cold Shrink Cable Joint - 24.9 to 56.4mm Dia - 3M LC4 Cable Joint

3M Cold Shrink Cable Joint - 37.8 to 84.3mm Dia - 3M LC5 Cable Joint

3M Cold Shrink Cable Joint - 37.8 to 84.3mm Dia - 3M LC6 Cable Joint

3M Cold Shrink Cable Termination 3 Core 35-50sqmm - 3M LCT1

3M Cold Shrink Cable Termination 3 Core 70-120sqmm - 3M LCT2

3M Cold Shrink Cable Termination 3 Core 150-185sqmm - 3M LCT3

3M Cold Shrink Cable Termination 3 Core 240-400sqmm - 3M LCT4

3M Cold Shrink Cable Joint - LC Joint Instruction

3M Cold Shrink Cable Termination - LCT Termination Instruction

3M Cold Shrink Cable Joints & Cable Terminations

3M Cold Shrink Cable End Caps.

3M Cold Shrink end caps environmentally seal and mechanically protect exposed cable ends using no tools, mastics or tapes. They are close-ended, tubular rubber sleeves that are factory expanded and loaded onto a removable core. When positioned over the end of a cable, or other cylindrical object, the cable end cap core is removed to provide a reliable seal that protects your cable ends from environmental damage including moisture, contamination, corrosion, ozone, ultra-violet and radiation.

3M Cold Shrink Cable End Caps - 11.6 to 20.9mm Dia - 3M EC1

3M Cold Shrink Cable End Caps - 15.9 to 30.1mm Dia - 3M EC2

3M Cold Shrink Cable End Caps - 26.0 to 49.2mm Dia - 3M EC3

3M Cold Shrink Cable End Caps - 45.5 to 84.3mm Dia - 3M EC4

3M Cold Shrink Cable End Caps

3M Cold Shrink Tubes.

3M PST Cold Shrink tubes are a series of open-ended, tubular rubber sleeves, which are factory expanded and assembled onto a removable core. 3M Cold Shrink tubes are supplied for field installation in this pre-stretched condition - the core is removed after the Cold Shrink tube has been positioned for installation over an inline connection, terminal lug, cable etc allowing the tube to shrink and form a waterproof seal - no torches or heat required.

3M Cold Shrink Tube - 7.8mm to 14.3mm Dia x 152mm - 3M 8423-6

3M Cold Shrink Tube – 9.9mm to 17.8mm Dia x 178mm – 3M 8425-7

3M Cold Shrink Tube – 10.2mm to 20.8mm Dia x 203mm – 3M 8425-8

3M Cold Shrink Tube – 13.0mm to 25.4mm Dia x 229mm – 3M 8426-9

3M Cold Shrink Tube – 13.0mm to 25.4mm Dia x 279mm – 3M 8426-11

3M Cold Shrink Tube – 17.5mm to 33.0mm Dia x 152mm – 3M 8427-6

3M Cold Shrink Tube – 17.5mm to 33.0mm Dia x 305mm – 3M 8427-12

3M Cold Shrink Tube – 17.5mm to 33.0mm Dia x 406mm – 3M 8427-16

3M Cold Shrink Tube – 24.0mm to 49.3mm Dia x 152mm – 3M 8428-6

3M Cold Shrink Tube – 24.0mm to 49.3mm Dia x 305mm – 3M 8428-12

3M Cold Shrink Tube – 24.0mm to 49.3mm Dia x 457mm – 3M 8424-18

3M Cold Shrink Tube – 24.0mm to 49.3mm Dia x 609mm – 3M 8428-24

3M Cold Shrink Tube – 32.2mm to 67.8mm Dia x 152mm – 3M 8429-6

3M Cold Shrink Tube – 32.2mm to 67.8mm Dia x 229mm – 3M 8429-9

3M Cold Shrink Tube – 32.2mm to 67.8mm Dia x 305mm – 3M 8429-12

3M Cold Shrink Tube – 32.2mm to 67.8mm Dia x 457mm – 3M 8429-18

3M Cold Shrink Tube – 42.6mm to 93.7mm Dia x 229mm – 3M 8430-9

3M Cold Shrink Tube – 42.6mm to 93.7mm Dia x 457mm – 3M 8430-18

3M Cold Shrink Tubes

3M Cold Shrink for the Construction Industry.

 

 'Don't play with fire - Stay cool with 3M'

Construction site fires cost lives, reputation and money – careless “hot-working” associated with heat shrink cable jointing is identified by the HSE as a serious contributor to fire risk.

 

3M Cold Shrink eliminates dangerous “hot-working” for safer LV-HV cable installations.

 

3M Cold Shrink for the Construction Industry

3M Cold Shrink for the Oil, Gas & Petrochemical Industry .

 

“Taking the Heat out of Hazardous Areas”

Heat shrink cable jointing needs naked flames – this poses serious H&S “hot-working” dangers.

 

Air, naked flames and the presence of atmospheric combustible substances trigger the Ignition Triangle.

 

Throughout the world specifiers, lead electrical engineers and their clients demand 3M Cold Shrink – a first class safety and service record without any hidden dangers.

 

 

EEMUA (Formerly OCMA) - High Voltage Cable Guide

3M Cold Shrink for the Oil, Gas & Petrochemical Industry

Cable Abandonment - 3M Cold Shrink - Step 1.

3M Cold Shrink Cable Abandonment Kits are suitable for cable types: XLPE/PVC Insulation, Lead Sheath, Steel Wire Armour, PVC Sheathed.

 

Also suitable for shipwiring Cables, EPR/GSWB and/or unarmoured cables up to and including 1.9/3.3kV single and multicore cables.

A complete kit with all the components required to abandon cables either temporarily or permanently. Provides environmental seal and mechanical protection, eliminates the requirements for heat during installation using 3M Cold Shrink technology.

 

Each kit includes Cold Shrink End Cap, Cold shrink Pre Stretched Tube, Armour Continuity, Scotch Tapes and Instructions.

Cable Abandonment

Cable Abandonment - 3M Cold Shrink - Step 1

Cable Abandonment - 3M Cold Shrink - Step 2.

Cable Abandonment

Cable Abandonment - 3M Cold Shrink - Step 2

Cable Abandonment - 3M Cold Shrink - Step 3.

Cable Abandonment

Cable Abandonment - 3M Cold Shrink - Step 3

Cable Abandonment - 3M Cold Shrink - Step 4.

Cable Abandonment

Cable Abandonment - 3M Cold Shrink - Step 4

Cable Abandonment - 3M Cold Shrink - Step 5.

Cable Abandonment

Cable Abandonment - 3M Cold Shrink - Step 5

Cable Abandonment - 3M Cold Shrink - Step 6.

Cable Abandonment

Cable Abandonment - 3M Cold Shrink - Step 6