T&D distribute Ellis Patents cable cleats providing safety critical support to vital cable circuits. Cable cleats must withstand peak short circuit forces generated by the actual cable installation - Ellis Patents 3rd party certified cable cleats provide peace of mind containment of low and high voltage cables.
supply LV-HV Cable Accessories, Jointing & Electrical Eqpt - we service UK and global businesses involved in cable installations, cable jointing, substation and electrical construction at LV, 11kV, 33kV and EHV - we export to utilities, power, construction, rail, mining, offshore, oil, gas and petrochemical industries.
|
|
|
|
ELLIS PATENTS CABLE CLEATS, CLAMPS & STRAPS
Short Circuit Protection |
|
UTILITY CABLE CLEATS LV HV |
Ellis Patents are global leaders in the innovation and manufacture of nylon, aluminium and stainless steel cable cleats - EP satisfy the operational requirements of the construction, oil, gas, rail, utilities, wind energy and power generation industries.
Holding Power is Ellis Patents guarantee that EP Cable Cleats will contain dangerous short circuit forces - protecting your people, power and plant. Without fail - specify Ellis Patents Cable Cleats.
|
|
104kA @ 600mm Spacings
132kA @ 300mm Spacings
Vulcan cable cleats for single, trefoil, quadrafoil and bundled cable installations - suits LV, 11kV-33kV BS6622 and BS7870 Triplex high voltage cables.
Made from stainless steel for non corrosive, high strength and permanent utility cable cleating with compact design.
LU Compliant Cable Cleats 1-085
|
REQUEST INFO
|
|
REQUEST QUOTE
|
|
|
|
|
|
|
|
TREFOIL CABLE CLEATS |
|
FIRE PROOF CABLE CLEATS |
Alpha cable cleats contain single core power cables in trefoil formation - lightweight, fast to install, strong and robust with unique design providing labour savings. Short circuit withstand test : 31.4kA RMS (72.4kA peak).
Alpha Trefoil Cable Cleats
LU Compliant Cable Cleats 1-085
|
|
BS8491 - 120 Minutes Fire, Water Jet & Direct Impact (F120) Tested
Phoenix stainless steel cable cleats are designed for installation with fire resistant and protection (FP) cables. Specified by the construction industry to reinforce and maintain FP cable circuit integrity - typical applications include emergency lighting, fire suppression, lift shafts and escape system circuits.
Phoenix Fire Proof Cable Cleats
LU Compliant Cable Cleats 1-085
|
REQUEST QUOTE
|
|
REQUEST QUOTE
|
|
|
|
|
|
|
|
INDUSTRIAL CABLE CLEATS |
|
ALUMINIUM CABLE CLEATS |
T&D distribute a comprehensive range of cable cleats suitable for industrial cable applications - EP provide cable cleats for single, trefoil, quadrafoil and bundled cable installations.
Emperor Cable Cleats
- Short circuit withstand tested to 156kA @ 600mm spacing
- 195kA @ 300mm spacing
- 235kA @ 225mm spacing
- Emperor Cable Cleats
Atlas Cable Cleat
Vari-Cleat Cable Cleat
Vulcan Cable Cleat
- Short circuit withstand tested to 104Ka @ 600mm spacing
- 132kA @ 300mm spacing
- Vulcan Cable Cleats
|
|
Aluminium cable cleats are designed to fix, retain and support cables in dry industrial or outdoor unpolluted applications - single and two bolt aluminium cable cleats can be epoxy coated for use in harsh environments.
Single Hole Aluminium Cable Cleats
Two Hole Aluminium Cable Cleats T&D distribute Ellis Patents single and two bolt hole fixing nylon cable cleats including standard polypropylene or LSF (low smoke zero halogen) flame retardant cable cleats.
Nylon & LSF Single Hole Cable Cleats
Nylon & LSF Two Hole Cable Cleats
|
REQUEST QUOTE
|
|
DOWNLOAD NEW T&D A-Z
REQUEST QUOTE
|
|
|
|
|
Vital Short Circuit Protection with Ellis Patents Cable Cleats
Ellis Patents are a leading voice in the campaign to have cable cleats reclassified as short-circuit protection devices. A move that would mean cable cleats would be placed on a parallel with fuses and circuit breakers. "This reclassification makes absolute sense. In the event of a cable fault, the forces between cables reach their peak in the first quarter cycle, which is the point that cable cleats earn their crust. In contrast, circuit breakers typically interrupt the fault after 3 or even 5 cycles by which time, if the cable cleats are underspecified, the cables will no longer be secure, but will be putting vital electrical installations and lives at unnecessary risk," says Paul Nolan UK Sales Manager, EP.
Importance of Offshore Cable Cleats
Dangers of Incorrectly Cleated Cables
No Cheating on Cleating IEC61914
Learn More - Request CPD Seminar
GO TO T&D NEWSLETTER ARCHIVE
|
Try T&D for LV Feeder Pillars and Pre-Wired Distribution Pillars
|