Blog

Stripping Bonded Semicon From 66kV Prysmian Cable (XLPE/Lead) Using Alroc LHS3 60-80 Tool

By Chris Dodds on 24th February, 2017

Pictured: Stripping Bonded Semicon From 66kV Prysmian Cable (XLPE/Lead) Using Alroc LHS3 60-80 Tool

Image By: Andy Radford - High Voltage Cable Jointer at Morgan Sindall

Alroc LHS3 semi-conductive screen stripping tools are used by high voltage cable jointers to strip bonded semi-con screens from 6.6kV, 11kV, 33kV and 66kV high voltage power cables.

ALROC 8YR0-LHS3

Stripping Bonded Semicon From 66kV Prysmian Cable (XLPE/Lead) Using Alroc LHS3 60-80 Tool

 

  • Further reading

Alroc DPC 10-45 Midspan Cable Jointing & Stripping Tools - Video

Alroc PF3/06 Cable Jointing Tool - Removing Medium Voltage Lead Covered (LC) Shield - Video

Alroc CWB18-60 Bonded Semi-Con Stripping & Removal Tool (11kV-33kV) - Video

 

Thorne & Derrick Specialist Electrical Distributor

Established since 1985, T&D distribute the most extensive range of LV, MV & HV Cable Jointing, Terminating, Pulling & Installation Equipment - contact us today for a competitive quotation.

Key Products : MV Joints & Terminations, Cable Cleats, Duct Seals, Cable Transits, Underground Cable Protection, Jointing Tools, Feeder Pillars, Cable Duct, Earthing & Lightning Protection, Electrical Safety, Cable Glands, Arc Flash Protection & Fusegear.

Distributors for : 3M, Alroc, Pfisterer, Nexans Euromold, Elastimold, Catu, Roxtec, Emtelle, Centriforce, Lucy Zodion, Alroc, Hivotec, Cembre, Prysmian, Ellis Patents, ABB & Furse.

Cable Joints Terminations Tools Cleats

 

Invitation

Thorne & Derrick are inviting you to join LinkedIn’s fastest growing Discussion Group : Low & High Voltage Power, Cabling, Jointing, & Hazardous Area Electricals (LV-HV).

Discussion subjects include cable installations, cable jointing, electrical substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.

Network, engage and promote your profile, company or products with over 10,000 influencers.

 

linkedin-logo Click Here To Join

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 24th February, 2017

Pictured: UKPN 33kV Primary Substation Construction - Swanland Solar Farm Image By: Dean Wilson Stone - Director at Wilson-Stone Contracting Dean is Director of a company that is a specialist civils contrator working with DNO's and off... Read More - UKPN 33kV Primary Su...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 14th February, 2017

Project: Cable Duct Sealing Application: Prevent water ingress and gas migration into a 33kV substation through LV-HV cable ducts using Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - the sequence of images show the insta... Read More - Sealing Substation C...

Category:  Cable Transits & Duct Sealing


By Chris Dodds on 10th February, 2017

Pictured: Pfisterer Connex Size 4 Cable Terminations Connecting 66kV Gas Cable Image: Dean Wilson - Owner Director at D.C.Cable Jointing Ltd T&D are Main Distributors & Stockists for the Pfisterer range of Medium Voltage Power... Read More - Pfisterer Connex Siz...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: Non-intrusive Maintenance By Lucy Electric Of Yorkshire Ringmaster, Oil Filled Transformer & LV Switchboard Image: Martin Avis - Energy Services at Lucy Electric T&D distribute Lucy Electric and Lucy Zodion low voltage di... Read More - Non-intrusive Mainte...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: Raychem 11kV Heat Shrink Cable Terminations (EPKT17E1XI) Connecting XLPE AWA Cables Image: Jim Andrews SPEC (Specialist Power Engineering Contracts) Cabling Contracts Manager. A before and after photograph of emergency HV cabling... Read More - Raychem 11kV Heat Sh...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: ABB EHV 275kV Cable Sealing Ends & GIS Cable Terminations Image: Richard Mason (EHV Cable Jointer) - Global Cabling Services Ltd Further reading 132kV EHV Gas Filled Straight Joint With Pfisterer Con... Read More - ABB EHV 275kV Cable ...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: Elcon Megarad Heat Shrink Cable Joint Kit (XLPE 12/20kV (24)kV)  Image: Morteza Sobhani (Expert Technical Support & Expert Installation of High Voltage Products) Cable Type is 1-Stranded Circular Conductor (1 x... Read More - Elcon Megarad Heat S...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: Pfisterer Connex 5s Cable Plugs Terminating Into Siemens HV Switchgear Image: Roger Wright - EHV Cable Jointer T&D are Main Distributors & Stockists for the Pfisterer range of Medium Voltage Power Products inclu... Read More - Pfisterer Connex 5s ...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: Cleating 11kV 3 Core & Single Core Cables With LV Pilot Cables Image: Sam Rowe Estimator at F B Taylor (Cable Contractors) Ltd  The 11kV cables have been pulled in and cleated using stainless steel trefoil and 2 bol... Read More - Cleating 11kV 3 Core...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: 500kV Deadend Rope Access Using The Skate System With SRP Image: Jim McDonald - Owner/Live Line Training at Powerline Training Consultants Further reading 500kV Live Line Working - Methods, Tools, Training & Galle... Read More - 500kV Deadend Rope A...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 10th February, 2017

Pictured: Cable Pulling 11kV 3 Core XLPE SWA Cables Into Trench  Image: Jim Andrews - SPEC (Specialist Power Engineering Contracts) Cabling Contracts Manager 3 x 3 core 95sqmm 11kV cables pulled into cable trench with 198 existin... Read More - Cable Pulling 11kV 3...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 3rd February, 2017

Pictured: Heat Shrink Transition Cable Splice/Joint 12kV Tyco - 400sqmm PILC - 500sqmm LC XLPE  Image: Andy O'Malley - EHV Cable Jointer     More From Andy O'Malley .... Lead Cable Jointing - Wher... Read More - Heat Shrink Transiti...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 27th January, 2017

Pictured: 11kV 3 Core Tyco Heat Shrink Termination (Pole-Mounted) Onto ABB MWK Surge Arresters Image: Beau Smithers HV Cable Jointer at S.I Cable Jointing Services Further reading 132kV Tyco Raychem Extra High Vol... Read More - 11kV 3 Core Tyco Hea...

Category:  Cable Jointing - PhotoBlog


By Chris Dodds on 27th January, 2017

EA Technology are hosting the CABLEx 2017 - the UK’s only major Power Cable Exhibition and Conference, on the 7th June 2017 at the Chester Racecourse venue.  Following the overwhelming success of our OHLEx2016: Overhead Lines Exhibition... Read More - CABLEx 2017 Power Ca...

Category:  Electrical Safety & Arc Flash


Page 1 of 110   |   Older >   |   Oldest > >